Verify whether the multivalve screws are properly fixed to the tank. The tightening torque shall be 3-4 Nm.
-
Verify whether the outlet fittings connections are properly fixed. The tightening torque shall not exceed 5 Nm.
-
Verify whether the inlet fittings connections are properly fixed. The tightening torque shall not exceed 5 Nm.
- Verify whether the manual tap is open.
- Check the electrical wires connections.
- If the electro valve is damaged or blocked by dirt contaminants present in the gas, maintain the component.
- Verify whether the installation procedure has been performed as per the Technical manual and installation guide
- Verify whether the installation procedure has been performed as per the Technical manual and installation guide.
- Verify whether the tank has been positioned in the vehicle as per the Technical manual and installation guide.
- Verify whether the multivalve size complies with the tank dimensions.
- Verify whether the installation procedure has been performed as per the Technical manual and installation guide
- Verify whether the tank has been positioned in the vehicle as per the Technical manual and installation guide.
- Verify whether the multivalve size complies with the tank dimensions.
- Verify whether the multivalve has not been damaged.
- Verify whether the multivalve has been set as per the Technical manual and installation guide.
- Verify whether the tank stem thread is intact.
- Check the proper tightening torque (200±10 Nm for valves with conical stem and 120±10 Nm for valves with cylindrical stem) and use the locking wrench provided by Tomasetto Achille Spa.
- Verify whether the outlet fittings are properly fixed. The tightening torque shall not exceed 5 Nm.
- Check the hoses integrity.
- Replace the valve, checking the proper tightening torque (as indicated at pt. 1).
- Replace the valve.
- Verify whether the external sealing O-ring is intact, and, if necessary, replace the component.
- Verify whether the manual valve is open.
- For valves equipped with electrovalve, check the electrical wires connections.
- Verify whether the manual valve of the filling valve is open.
- Verify whether the fitting is untied. The tighten torque shall be 10 ± 2 Nm.
- Check the hoses connection and, in particular, whether nuts and bi-conical joints are properly fixed. The tightening torque shall not exceed 5 Nm.
- Verify whether dirt contaminants are present in the reducer and, if necessary, maintain it with the proper revision kit, as provided by Tomasetto Achille Spa.
- Verify whether the system settings are correct, in accordance with the supplier’s Electronic Control Unit guidebook.
- Verify whether the fitting is damaged and, if necessary, replace the reducer.
- Check the hose connection.
- Maintain the reducer with the revision kit provided by Tomasetto Achille Spa.
- Check the hoses integrity and the hose clamps tightening.
- Maintain the reducer replacing the water pipes.
- Maintain the reducer with the revision kit provided by Tomasetto Achille Spa.
- Verify whether the installation procedure of all the components has been performed as per the Technical manual and installation guide.
- Verify whether the electro valve has been damaged.
- Check the hoses integrity.
- Verify whether dirt contaminants are present in the reducer.
- Verify, in traditional kits, whether the system has been set as per the Technical manual and installation guide.
- Check the water circuit connections.
- Verify whether the reducer has been positioned in the vehicle as per the Technical manual and installation guide.
- Verify, with proper gas detectors (as water with soap or electronic sniffers), whether the tap and the connections are not damaged, and, if necessary, replace the components.
- Maintain the electro valve with the revision kit provided by Tomasetto Achille Spa.
- If the sealing seat or the rail body are damaged, replace the product.
- Check the coils electrical connections.
- Maintain the electro valve with the revision kit provided by Tomasetto Achille Spa.
- Maintain the plunger with the revision kit provided by Tomasetto Achille Spa.
- Verify whether the nozzles measure complies with the system specifications, as reported in the ECU guidebook and, if necessary, replace them.